Catalog
Manual
Product Introduction
Product Features
Technical Details
Applications
Product Introduction
The MS-802 Secondary standard pyranometer is a reliable reference sensor to measure global broad-band radiation with high precision. It is used as a standard in PV research and climatological studies around the world.
A high quality double-dome construction is adopted to improve the accuracy of the measurement and to minimize unwanted thermal offsets. The ventilation unit of the MS-802F model will reduce the deposition of dust, dew, frost, snow.
The MS-802 pyranometers are manufactured in a consistent way followed by strict quality inspection and performance evaluation. For each sensor the directional response and temperature dependency are measured and validated through a measurement report that comes with the sensor. EKO provides a unique calibration compliant to the international standards defined by ISO/IEC17025/9847.
Product Features
- ISO 9060 Secondary standard
- Temperature compensation
- ISO 17025 certified calibration
- 5 years warranty
- MS-802F with ventilation
Technical Details
ISO 9060 classification | Secondary Standard |
Output | Analog (mV) |
Response time 95% | < 5 Sec. |
Zero Offset A 200W/m² | < 6 W/m² |
Zero Offset B 5K/hr | +/- 2 W/m² |
Non-stability change/1 year | +/- 0.5 % |
Non-linearity at 1000W/m² | +/- 0.2 % |
Directional response at 1000W/m² | < 10 W/m² |
Spectral selectivity 0.35-1.5µm | +/- 1 % |
Temperature response -10°C to 40°C | < 1 % |
Temperature response -20°C to 50°C | < 2 % |
Tilt response at 1000W/m² | +/- 0.2 % |
Sensitivity | Approx. 7 µV/W/m² |
Impedance | Approx. 500 Ω |
Operating temperature range | -40 – 80 °C |
Irradiance range | 0 – 4000 W/m² |
Wavelength range | 285 – 3000 nm |
Ingress protection IP | 67 |
Cable length | 10 m |
Applications
- Accurate solar radiation measurements
- DHI Measurements
- Solar Radiation Measurements in PV applications
- Solar radiation energy budgets studies