Product Introduction
Product Features
Technical Details
Applications
Product Introduction
The MS-60 is a ISO 9060 First class pyranometer with analog output and improved performance. The new double dome constructions provides lower offsets and cosine errors. The MS-60A and MS-60M provide a digital output (4-20mA or Modbus 485 RTU). The MS-60/60A/60M can be used with the optional MV-01 ventilator / heater.
The MS-60 pyranometers are manufactured in a consistent way followed by strict quality inspection and performance evaluation. EKO provides a unique calibration compliant to the international standards defined by ISO/IEC17025/9847. The sensor has 5 years warranty with 2 years re-calibration interval are recommended and it is no longer necessary to change the desiccant.
The MS-60A is a MS-60 with built in 4-20mA converter is compatible to the industrial output standards. The new double dome constructions provides lower offsets and cosine errors. The MS-60A can be used with the optional MV-01 ventilator / heater.
The MS-60M is a MS-60 with built in MODBUS 485 RTU converter is compatible to the industrial output standards. The new double dome constructions provides lower offsets and cosine errors. The MS-60M can be used with the optional MV-01 ventilator / heater.
Product Features
MS-60 Pyranometer | MS-60A Pyranometer | MS-60M Pyranometer |
ISO 9060 First class
Analog output ISO 17025 certified calibration Optional ventilator MV-01 5 years warranty |
ISO 9060 First class
Compact and light weight Industrial sensor outputs (4-20mA) ISO 17025 certified calibration Optional ventilator MV-01 5 years warranty |
ISO 9060 First class
Compact and light weight Industrial sensor outputs (MODBUS RTU) ISO 17025 certified calibration Optional ventilator MV-01 5 years warranty |
Technical Details
MS-60 | MS-60A | MS-60M | |
ISO 9060 classification | First Class | First Class | First Class |
Output | Analog (mV) | Digital (4-20mA) | Digital (Modbus RTU) |
Response time 95% | < 18 Sec. | < 18 Sec. | < 18 Sec. |
Zero Offset A 200W/m² | < 5 W/m² | < 5 W/m² | < 5 W/m² |
Zero Offset B 5K/hr | +/- 2 W/m² | +/- 2 W/m² | +/- 2 W/m² |
Non-stability change/1 year | +/- 1.5 % | +/- 1.5 % | +/- 1.5 % |
Non-linearity at 1000W/m² | +/- 1 % | +/- 1 % | +/- 1 % |
Directional response at 1000W/m² | < 18 W/m² | < 18 W/m² | < 18 W/m² |
Spectral selectivity 0.35-1.5µm | +/- 1 % | +/- 1 % | +/- 1 % |
Temperature response -10°C to 40°C | < 3 % | < 3 % | < 3 % |
Temperature response -20°C to 50°C | < 4 % | < 4 % | < 4 % |
Tilt response at 1000W/m² | +/- 1 % | +/- 1 % | +/- 1 % |
Sensitivity | Approx. 10 µV/W/m² | – | – |
Impedance | 100 Ω | – | – |
Operating temperature range | -40 – 80 °C | 40 – 80 °C | 40 – 80 °C |
Irradiance range | 0 – 2000 W/m² | 0 – 2000 W/m² | 0 – 2000 W/m² |
Wavelength range | 285 – 3000 nm | 285 – 3000 nm | 285 – 3000 nm |
Ingress protection IP | 67 | 67 | 67 |
Cable length | 10 m | 10 m | 10 m |
Applications
- Accurate solar radiation measurements
- DHI Measurements
- Solar Radiation Measurements in PV applications
- Solar radiation energy budgets studies